Administration alarm system alternating-current ambient amended by CGFR ammeter amperes applicable approved armored arranged automatically boxes branch circuit bulkhead cable cargo tanks chapter circuit breaker Class Coast Guard conductors connected construction contracted for prior cord cuit current-carrying capacity deck Department direct-current disconnecting means door electrical emergency lighting emergency source enclosure engine order engine order telegraph equipment Federal Register fixture wire flammable fuses ground grounded conductor horsepower indicator installed insulation intrinsically safe Knife switches lamps less lifeboat lighting and power located loudspeaker Marine Inspection ment motor controllers normal November 19 Office operation overcurrent device overcurrent protection overload panelboards paragraph passenger vessels percent portable portable cord prior to November propulsion rating or setting Regulations relay revised ship's service Standard Stat steering gear storage battery subchapter Subpart SUBTITLE supply switchboard Table tank vessels temperature Thermoplastic tion ventilation vessels contracted voltage volts watertight wheelhouse
مقاطع مشهورة
الصفحة 80 - Apparatus enclosed in a case that is capable of withstanding an explosion of a specified gas or vapor which may occur within it and of preventing the ignition of a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and which operates at such an external temperature that a surrounding flammable atmosphere will not be ignited thereby.
الصفحة 121 - The exit from every main compartment occupied by passengers or crew shall be continuously lighted by an emergency lamp. The power for these emergency...
الصفحة 23 - In the case of classed vessels, upon specific request by the submitter, the American Bureau of Shipping will arrange to forward the necessary plans to the Coast Guard indicating Its action thereon. In this case, the plans will be returned as noted In subparagraph (2) of this paragraph.
الصفحة 81 - Class I locations are those in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitible mixtures.
الصفحة 15 - Intrinsically safe equipment and wiring shall not be capable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentration. Abnormal conditions shall include accidental damage to any field-installed wiring, failure of electrical components, application of overvoltage. adjustment and maintenance operations, and other similar conditions.
الصفحة 16 - Passenger. A passenger is every person other than the master and the members of the crew or other persons employed or engaged in any capacity on board a vessel in the business of that vessel.
الصفحة 66 - Any mot or of one horsepower or less which is portable, is manually started and is within sight from the starter location, shall be considered as protected against overcurrent by the overcurrent device protecting the conductors of the branch circuit. This branch circuit overcurrent device shall not be larger than that specified by table...
الصفحة 16 - For the purpose of this subchapter motorboats are included under the term "vessel" unless specifically noted otherwise. The various classes of motorboats are as follows: Class A — Any motorboat less than 16 feet In length. Class 1 — Any motorboat 16 feet or over and less than 26 feet In length. Class 2 — Any motorboat 26 feet or over and less than 40 feet In length. Class 3 — Any motorboat 40 feet or over and not more than 65 feet In length. § 110.15-128 Nuclear energy, radioactive material,...
الصفحة 59 - ... for the largest motor connected to the branch circuit plus an amount equal to the sum of the full load current ratings of all other motors connected to the circuit.
الصفحة 29 - Separately excited propulsion generators should be provided with more than one means of excitation. Exciters may be either direct connected or independent generating...